Replace Surge Protector; (Tcm) - Graco Reactor 2 Repair Parts

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2:
Table of Contents

Advertisement

Repair
Replace Surge
Surge Protector
Protector
Replace
Replace
Surge
Protector
1. Loosen connections on terminals 1 and 3 on
CB13. See
Electrical Schematics, page
2. Loosen connections on input to power
supply (805) on N and L connections. See
Electrical Schematics, page
3. Remove two screws (612), washers (611),
and surge protector (705) from enclosure.
4. Install new surge protector (705) in reverse
order.
NOTE:
NOTE: Wire on both the circuit breaker and
NOTE:
power supply are interchangeable.
Figure 10 Surge Protector
72
Replace Temperature
Replace
Replace
Module (TCM)
Module
Module
105.
1. Perform
2. Open the electrical enclosure door.
105.
3. Disconnect all connectors from the TCM
4. Remove four nuts (610) and TCM (602).
5. Install new TCM module (602). Reassemble
6. Update software by inserting an upgrade
Figure 11 Replace TCM
Temperature Control
Temperature

(TCM)

(TCM)
Shutdown, page
(602).
parts in reverse order.
token into the ADM and cycling system
power. Wait until the update is complete
before removing the token and restarting
the system.
Control
Control
50.
334946J