Troubleshooting
Error
Location
Error
Error
Location
Location
CACT
TCM
DADX
HCM
F9FA
ADM
20
Type
Description
Type
Type
Description
Description
TCM Communica-
tion Error
Pump Runaway
Flow Cutback Low
Inlet A Pressure
Cause
Cause
Cause
Solution
Solution
Solution
Module does not
Insert a system token
have software
into the ADM module
and cycle the power.
Wait until the upload
is complete before
removing the token.
No 24 VDC
Green light on each
supply to module
module should be lit.
If green light is not lit,
check to make sure each
CAN cable connection is
tight. Verify the power
supply is outputting 24
VDC. If not, check power
supply wiring. If wiring is
okay, replace the power
supply.
Loose or broken
Check the CAN cables
CAN cable
running between GCA
modules and tighten of
needed. If the problem
still persists move
each cable around the
connector and watch the
flashing yellow light on
the GCA modules.
the yellow light stops
flashing, replace the CAN
cable.
Flow rate is too
Mix chamber too large
large
for system selected. Use
mix chamber rated for
system.
Ensure the system has
chemical and the feed
pumps are operating
correctly.
No material in pumps.
Verify pumps are
supplying chemical.
If necessary, replace or
refill drums.
Inlet ball valves are
closed. Open ball valves.
ISO Inlet pressure
Increase ISO feed pump
is too low
pressure.
ISO inlet flow is
Change to larger ISO feed
too low
pump.
If