Troubleshooting
Error
Location
Error
Error
Location
Location
P6FB
HCM
26
Type
Description
Type
Type
Description
Description
Pressure Sensor
Error Inlet B
Cause
Cause
Cause
Solution
Solution
Solution
Bad sensor
Check if the error
follows the inlet sensor.
Disconnect inlet sensor
cables from the HCM
(connectors 8 and
9). Reverse A and B
connections and check if
the errors follows. If the
error follows the sensor,
replace the inlet sensor.
Inlet sensors not
If inlet sensors are not
installed
installed, inlet sensors
should be disabled on
the System Setup screen.
Loose/bad
Check to ensure inlet
connection
sensor is properly
installed and all wires are
properly connected.
Bad sensor
Check if the error
follows the inlet sensor.
Disconnect inlet sensor
cables from the HCM
(connectors 8 and
9). Reverse A and B
connections and check if
the errors follows. If the
error follows the sensor,
replace the inlet sensor.
334946J