12. Use soft keys to select and confirm
desired option. Press More soft key
to toggle among pages for Peak Over
of Ext-1 and Ext-2, respectively.
When the occurrence of peak over-range happens
in Auto range mode for external input, user is able
to define a measurement range to switch to. The
available options for each mode are listed below.
When it is under CF3 mode for External Sensor 1.
Off/2.5V/5V/10V
When it is under CF6/6A mode for External Sensor 1.
Off/1.25V/2.5V/5V
When it is under CF3 mode for External Sensor 2.
Off/50mV/100mV/200mV/500mV/1V/2V
When it is under CF6/6A mode for External Sensor 2.
Off/25mV/50mV/100mV/250mV/0.5V/1V
Off
 The available external is based on which external
sensor input is enabled beforehand. Be aware
that it requests to enable either Ext1 or Ext2 prior
to enabling the skipping config for external.
 The available options for Peak Over field are limited
within the selected options from the External Sensor
1 and External Sensor 2 sections above.