Safety Instructions To maintain the probe in a correct and safe condition, observe generally accepted safety procedures in addition to the precautions specified in this section. The overall safety of any system incorporating this product is the responsibility of the assembler of the system. Symbols These symbols appear on the probe and accessories or in this manual to alert you to important safety considerations.
PRODUCT OVERVIEW + 20 V, 200 MHz T3LVD20-200: Teledyne Test Tools new T3LVD20-200 low voltage differential probe is a wide bandwidth active differential voltage probe, featuring 200 MHz bandwidth, + 20V (DC + Pk AC), fast and accurate waveform capture, measurement accuracy of 2% and low test circuit loading.
Page 6
1) Measurement input cable The T3LVD20-200 measurement input cables connecting to the DUT. The connection between the T3LVD20-200 input cables and the DUT will usually be made using grippers or alligator clip connectors (supplied). 2) Offset adjustment This button allows the user to remove any common mode offset up to + 60V. 3) Probe head to control box connection cable This is a fixed connection cable between the probe head and the control box, of approximately 70 cm in length.
USB Cable Wall Socket USB Power Supply (no photo). Accessories Alligator Clips Gripper Clips Test Hook BNC 50Ω Feedthrough Termination Adapter BNC Output Cable: 1 m, BNC - BNC Coaxial Cable USB Cable: 1.5 m, Type A Male - Type B Male Wall Socket USB Power Supply: Input: 100 V - 240 V, Output: 5 V / 1 A Making Measurements •...
Make sure that the oscilloscope connected to this device's output BNC connector is equipped with protective earthing with double-insulation construction. • Do not allow the T3LVD probe to get wet, and do not take measurements with wet hands. This may cause an electric shock. •...
Maintenance • Keep the probe dry and clean. • Clean the probe with a dry cloth, do not use liquid cleaning agents. • After use put the probe back in its case and store in a clean and dry place out of the sun. •...
Page 10
124mm x 49mm x 27mm Pollution Level Operating Temperature C - 50 Storage Temperature C - 70 Operating Humidity < 85% RH Storage Humidity < 90% RH Operating Altitude 3000m Storage Altitude 12000m Warranty 1 Year Return To Teledyne LeCroy Page 7...
Certifications Teledyne LeCroy certifies compliance to the following standards as of the date of publication. As standards evolve, these may no longer be current. See the Declaration of Conformity shipped with your product for current certifications. EMC Compliance EC Declaration of Conformity - EMC The current probes meet the intent of EC Directive 2014/30/EU for Electromagnetic Compatibility.
EUROPEAN CONTACT:* Teledyne GmbH – LeCroy Division Im Breitspiel 11c D-69126 Heidelberg Germany Tel: (49) 6221 82700 Australia & New Zealand Declaration of Conformity - EMC The probe complies with the EMC provision of the Radio Communications Act per the following...
Page 13
Restriction of Hazardous Substances (RoHS) The product and its accessories conform to the 2011/65/EU RoHS2 Directive inclusive of any further amendments or modifications of said Directive. See package inserts for other environmental certifications. CHINA RoHS 2 Unless otherwise specified, all the materials and processes are compliant with the latest requirements of China RoHS 2.