[:INPut]:VOLTage:AUTO

Description
Syntax
Query Syntax
Parameter
Return parameter 0
Example

[:INPut]:VOLTage:CONFig

Description
Syntax
Query Syntax
Parameter/
Return parameter
Example

[:INPut]:VOLTage:POJump

Description
Syntax
148
Sets or returns the voltage auto range on/off state.
[:INPut]:VOLTage:AUTO {<Boolean>|OFF|ON}
[:INPut]:VOLTage:AUTO?
<Boolean>0 OFF
<Boolean>1 ON
Turn the voltage auto range function off.
1
Turn the voltage auto range function on.
:INPUT:VOLTAGE:AUTO ON
:INPUT:VOLTAGE:AUTO?
->:INPUT:VOLTAGE:AUTO 1
Sets or returns the valid voltage range.
[:INPut]:VOLTage:CONFig {ALL|<Voltage>[,Voltage]...}
[:INPut]:VOLTage:CONFig?
ALL
All ranges are valid.
<Voltage>
See(:INPut:VOLTage:RANGe).
:INPUT:VOLTAGE:CONFIG 300,150,30
:INPUT:VOLTAGE:CONFIG?
->:INPUT:VOLTAGE:CONFIG 300.0E+00,150.0E+00,
30.0E+00
Sets or returns the jump destination range that is
used when a voltage peak over-range occurs.
[:INPut]:VOLTage:POJump {OFF|<Voltage>}
T3PM1100 User Manual
Set
Query
Set
Query
Set
Query