Teledyne Everywhereyoulook T3PM1100 User Manual page 20

Digital power meter
Hide thumbs Also See for Everywhereyoulook T3PM1100:
Table of Contents

Advertisement

GND Terminal
Voltage/Current
input terminal
External Input 1/2
Warning
20
CURRENT
I
I
20A MAX
GPIB
Connects output signal to the EXT1
EXT1
terminal which receives up to 10V, or
10V MAX
the EXT2 terminal that receives at the
EXT2
maximum of 2V. See page 53 for setting.
2V MAX
Do not use damaged device. Before using the
equipment, check its housing first to sure ensure
there are no cracks. Do not operate this device in
an environment containing explosive gases, steam
or dust.
The maximum measurable current and voltage are
600 V and 20A for voltage and current terminals of
the rear panel of the T3PM1100. Do not input
exceeded voltage and current, otherwise it will burn
the device.
The maximum input voltage are 10 V and 2V for
EXT1 and EX2 terminals of the rear panel of the
T3PM1100. Do not input exceeded voltage,
otherwise it will burn the device.
Always use the supplied cable for connection.
Before connecting the device, observe all the safety
symbols marked on the device.
Turn off the power to the device and the application
system before connecting I/O terminals.
Do not install replacement parts on the device or
perform any unauthorized modifications.
T3PM1100 User Manual
Connects the GND (ground)
terminal to the earth ground.
Voltage/Current
VOLTAGE
V
EXT1
input terminal is
10V MAX
V
EXT2
used to connect
the main
2V MAX
600V MAX
CAT II 600V
measurement
signals.

Advertisement