Teledyne Everywhereyoulook T3PM1100 User Manual page 210

Digital power meter
Hide thumbs Also See for Everywhereyoulook T3PM1100:
Table of Contents

Advertisement

The extended event register receives information about changes in the
condition register, which indicates the instrument's internal condition.
The information is the result of edge detection performed by the
transition filter.
The following table lists the bit definitions for the condition register:
Bit
Name
0
Updating
1
Integrate Busy
2
Integrate Time Busy
3
Not Used
4
Frequency Over
5
Store Busy
6
Measured Data Over
7
Voltage Peak Over
8
Current Peak Over
9
Not Used
10
Not Used
11
Not Used
12
Not Used
13
Not Used
14
Not Used
15
Not Used
210
Decimal
1
The measured data is being
updated. UPD changing from 1 to
0 indicates that updating has been
completed.
2
During integration.
4
The integration timer is operating.
8
(Reserved for future use)
16
The frequency is outside the
measurement range.
32
During storage.
64
The voltage or current exceeds its
range.
128
A peak over-range is detected in
the voltage.
256
A peak over-range is detected in
the current.
512
(Reserved for future use)
1024
(Reserved for future use)
2048
(Reserved for future use)
4096
(Reserved for future use)
8192
(Reserved for future use)
16384
(Reserved for future use)
32768
(Reserved for future use)