[:Input]:Current; [:Input]:Current:range - Teledyne Everywhereyoulook T3PM1100 User Manual

Digital power meter
Hide thumbs Also See for Everywhereyoulook T3PM1100:
Table of Contents

Advertisement

Query Syntax
Parameter/
Return parameter
Example

[:INPut]:CURRent

Description
Query Syntax
Return parameter <String>

[:INPut]:CURRent:RANGe

Description
Query
Query Syntax
Parameter/
Return parameter
[:INPut]:VOLTage:POJump?
OFF
No jump destination voltage range.
<Voltage>
See(:INPut:VOLTage:RANGe).
:INPUT:VOLTAGE:POJUMP 600V
:INPUT:VOLTAGE:POJUMP?
->:INPUT:VOLTAGE:POJUMP 600.0E+00
Returns all current measurement settings.
[:INPut]:CURRent?
Sets or returns the current range.
[:INPut]:CURRent:RANGe
{<Current>|(EXTernal<x>,<Voltage>)}
[:INPut]:CURRent:RANGe?
<x>
1,2(EXT1,EXT2)
<Current> 5, 10, 20, 50, 100, 200, 500(mA)
1, 2, 5, 10, 20(A) when the crest factor is
set to 3.
2.5, 5, 10, 25, 50, 100, 250(mA)
0.5, 1, 2.5, 5, 10(A) when the crest factor
is set to 6 or 6A.
EXTernal1
2.5, 5, 10(V) when the crest factor is set to
3.
<Voltage>
1.25, 2.5, 5(V) when the crest factor is set
to 6 or 6A.
EXTernal2 50, 100, 200, 500,(mV), 1, 2(V) when the
crest factor is set to 3.
COMMAND OVERVIEW
Query
Set
Query
149

Advertisement

Table of Contents
loading