Ul Standards Compliance For Dc Power Supply Input - YASKAWA GA800 Technical Reference

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

5.3 UL Standards
6-Phase/12-Pulse 400 V Class
Table 5.22 Factory-Recommended Branch Circuit Protection: 6-Phase/12-Pulse 400 V Class
Drive Model
T103
T140
T168
T208
T250
T302
Electric Code Compliance
The user must provide short circuit protection to protect input branch circuits as specified by the National Electric
Code (NEC), the Canadian Electric Code, Part 1 (CEC), and local codes.

UL Standards Compliance for DC Power Supply Input

To comply with UL Standards, install a fuse for the DC power supply input.
Figure 5.24
shows a wiring example for a DC power supply that has two drives connected in parallel.
WARNING! Electrical Shock Hazard. Do not ground the main circuit bus. Incorrect wiring can cause serious injury or death.
Note:
Install a fuse for each drive when operating more than one drive. If one fuse blows, replace all fuses.
Refer to
Table 5.23
and
Table 5.24
Drive Model
2004
2006
2008
2010
2012
2018
2021
292
Semiconductor Protection Fuse
Manufacturer: EATON/Bussmann
FWH-200B
FWH-225A
FWH-225A
FWH-275A
FWH-300A
FWH-350A
Figure 5.24 Wiring Example for DC Power Supply Input
for the recommended fuses.
Table 5.23 Recommended Fuse (Three-Phase 200 V Class)
Fuse
Manufacturer: Bussmann
Model
Qty
FWH-45B
2
FWH-45B
2
FWH-45B
2
FWH-45B
2
FWH-50B
*1
FWH-80B
2
*1
FWH-100B
FWH-80B
2
*1
FWH-100B
FWH-80B
2
*1
FWH-100B
Semiconductor Protection Fuse
Drive Model
Manufacturer: EATON/Bussmann
T371
T414
T477
T568
T605
T720
Drive Model
Model
2030
FWH-125B
2042
FWH-150B
2056
FWH-200B
2070
FWH-225A
2082
FWH-250A
2110
FWH-250A
2138
FWH-300A
2169
FWH-350A
2211
FWH-450A
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
FWH-400A
FWH-450A
FWH-600A
FWH-600A
FWH-800A
FWH-800A
Fuse
Manufacturer: Bussmann
Qty
2
2
2
2
2
2
2
2
2

Advertisement