Parameters Automatically Set
n5-02 [Motor Inertia Acceleration
Time]
n5-03 [Feed Forward Control
Gain]
*1
The drive automatically sets C1-08 [Deceleration Time 4] only when C1-11 [Accel/Decel Time Switchover Freq] ≠ 0.
*2
When L2-29 = 0 [Kinetic Energy Backup Method = Single Drive KEB Ride-Thru 1], the drive will automatically adjust C1-09 [Fast Stop
Time] and will not adjust L2-06 [Kinetic Energy Backup Decel Time]. If the Fast Stop time must not change, do not do KEB Tuning.
*3
When L2-29 = 1, 2, or 3 [Kinetic Energy Backup Method = Single Drive KEB Ride-Thru 2, System KEB Ride-Thru 1, or System KEB
Ride-Thru 2], the drive will automatically adjust L2-06 [Kinetic Energy Backup Decel Time].

Precautions before Auto-Tuning

Examine the topics in this section before you start Auto-Tuning.
Prepare for Basic Auto-Tuning
• You must input data from the motor nameplate or motor test report to do Auto-Tuning. Make sure that this data is
available before you do Auto-Tuning.
• For best performance, make sure that the drive input supply voltage is equal to or more than the motor rated
voltage.
Note:
Better performance is possible when you use a motor with a rated voltage that is less than the input supply voltage (by 20 V for 200 V class
models or by 40 V for 400 V class models). This is very important when you operate the motor at more than 90% of base speed, where high
torque precision is necessary. If the input power supply is equal to the motor rated voltage, the drive output voltage will not be sufficient and
performance will decrease.
• Push
on the keypad to cancel Auto-Tuning.
• If a Safe Disable input signal is input to the drive during Auto-Tuning, Auto-Tuning measurements will not
complete successfully. If this occurs, cancel Auto-Tuning, then do it again.
Table 4.16
shows the status of multi-function input/output terminals during Auto-Tuning.
Auto-Tuning Type
Rotational
Induction Motor Auto-Tuning
Stationary
Rotational
PM Motor Auto-Tuning
Stationary
EZ Tuning
Stationary
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Inertia Tuning
ASR Tuning
x
x
Table 4.16 Status of Input/Output Terminals during Auto-Tuning
Mode
Rotational Auto-Tuning
Stationary Auto-Tuning 1
Line-to-Line Resistance
Z-Pulse Offset (Pole Position)
Rotational (Ld, Lq, R, back-EMF)
Manual Entry w/ Motor Data Sheet Disabled
PM Stationary Auto-Tuning
PM Stationary Auto-Tuning for
Stator Resistance
Motor Parameter Setting
Line-to-Line Resistance
Deceleration Rate Tuning
x
-
x
-
Multi-Function Input
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
4.8 Auto-Tuning
KEB Tuning
-
-
Digital Output
Functions the same as during usual
operation.
Keeps the status at the start of
Auto-Tuning.
Keeps the status at the start of
Auto-Tuning.
• PRG: 09012 and earlier: Keeps
the status at the start of Auto-
Tuning.
• PRG: 09013 and later:
Functions the same as during
usual operation.
Functions the same as during usual
operation.
Keeps the status at the start of
Auto-Tuning.
Keeps the status at the start of
Auto-Tuning.
Keeps the status at the start of
Auto-Tuning.
Keeps the status at the start of
Auto-Tuning.
Keeps the status at the start of
Auto-Tuning.
221