L4: Speed Detection; L5: Fault Restart - YASKAWA GA800 Technical Reference

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

11.11 L: Protection Functions
No.
Name
(Hex.)
L3-38
Current Limit I Time @
Accel
(11D2)
Expert
L3-39
Current Limit Filter Time
@Accel
(11D3)
L3-40
Current Limit S-Curve @
Acc/Dec
(11D4)

L4: Speed Detection

No.
Name
(Hex.)
L4-01
Speed Agree Detection
Level
(0499)
L4-02
Speed Agree Detection
Width
(049A)
L4-03
Speed Agree Detection
Level (+/-)
(049B)
L4-04
Speed Agree Detection
Width (+/-)
(049C)
L4-05
Fref Loss Detection
Selection
(049D)
L4-06
Frequency Reference
@Loss of Ref
(04C2)
L4-07
Speed Agree Detection
Selection
(0470)

L5: Fault Restart

No.
Name
(Hex.)
L5-01
Number of Auto-Restart
Attempts
(049E)
L5-02
Fault Contact at Restart
Select
(049F)
618
V/f
CL-V/f
OLV
CLV
AOLV
Suppresses current hunting and overshooting that occurs when the drive stalls during
acceleration. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant to adjust the acceleration rate when L3-01 = 3 [Stall Prevention
during Accel = Current Limit Method]. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to enable and disable the best S-curve characteristic used for current-
limited acceleration.
0 : Disable
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the level to detect speed agree or motor speed.
Sets the level to detect speed agree or motor speed when H2-01 to H2-03 = 2, 3, 4, 5
[MFDO Function Selection = Speed Agree 1, User-set Speed Agree 1, Frequency
Detection 1, Frequency Detection 2].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the width to detect speed agree or motor speed.
Sets the width to detect speed agree or motor speed when H2-01 to H2-03 = 2, 3, 4, 5
[MFDO Function Selection = Speed Agree 1, User-set Speed Agree 1, Frequency
Detection 1, Frequency Detection 2].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the level to detect speed agree or motor speed.
Sets the speed agree detection level or motor speed detection level when H2-01 to H2-03 =
13, 14, 15, 16 [MFDO Function Selection = Speed Agree 2, User-set Speed Agree 2,
Frequency Detection 3, Frequency Detection 4].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the width to detect speed agree or motor speed.
Sets the width to detect speed agree or motor speed when H2-01 to H2-03 = 13, 14, 15, 16
[MFDO Function Selection = Speed Agree 2, User-set Speed Agree 2, Frequency
Detection 3, Frequency Detection 4].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the operation when the drive detects a loss of frequency reference.
0 : Stop
1 : Run at (L4-06 x Last Reference)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference as a percentage to continue drive operation after it detects a
frequency reference loss. The value is a percentage of the frequency reference before the
drive detected the loss.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the condition that activates speed detection.
0 : No Detection during Baseblock
1 : Detection Always Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of times that the drive will try to restart.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that sends signals to the MFDO terminal set for Fault [H2-xx = E] while
the drive is automatically restarting.
0 : Active Only when Not Restarting
1 : Always Active
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Default
Ref.
(Range)
10.0
984
(0.0 - 100.0)
100.0 ms
985
(1.0 - 1000.0 ms)
0
985
(0, 1)
Default
Ref.
(Range)
Determined by A1-02
985
(Determined by A1-02)
Determined by A1-02
985
(Determined by A1-02)
Determined by A1-02
985
(Determined by A1-02)
Determined by A1-02
986
(Determined by A1-02)
0
986
(0, 1)
80.0%
986
(0.0 - 100.0%)
0
986
(0, 1)
Default
Ref.
(Range)
0
987
(0 - 10 times)
0
987
(0, 1)

Advertisement

Table of Contents
loading