Electrical; Voltage And Power - Konica Minolta Magicolor 3300 User Manual

Konica minolta magicolor 3300: users guide
Hide thumbs Also See for Magicolor 3300:
Table of Contents

Advertisement

RAM
Optional RAM
System
software
Optional
Internal IDE
hard disk
Time-of-day
clock
Job accounting Crown job accounting; requires an optional internal IDE
Warning
function

Electrical

Voltage and Power

Voltage and
frequency
Phase
Power
consumption
Certification
Engine and Controller Specifications
Type: PC-100 Compliant SDRAM DIMMs
Base system RAM: 256 MB
Total RAM: Upgradable to 512 MB (through 2 DIMM
connectors)
64, 128, and 256 MB DIMMs
For information about DIMMs recommended for
your printer, see the magicolor 3300 Answer Base
at printer.konicaminolta.net/support
Softloadable; stored in Flash ROM
Up to 2.2 GB; must be PIO Mode 4 compatible
For information about hard disks recommended for
your printer, see the magicolor 3300 Answer Base
at printer.konicaminolta.net/support
Optional
hard disk drive
Optional, BuzzBox (light/buzzer printer warning device);
operates over a parallel connection; Americas only
US: 120 volts 10% at 60 Hz 2 Hz
International: 220-240 volts +6/-10% at 50 Hz 2 Hz
Single
Mode
Operation
Standby
Power saver
ENERGY STAR compliant
Average
Maximum
450 watts
850 watts
180 watts
850 watts
45 watts