Current

Mode
Operation (100–120 V)
Operation (220–240 V)
Standby Power saver mode (100–120 V)
Standby Power saver mode (220–240 V)

Environmental

Acoustic noise
data by
ISO 7779
Relative
humidity
Temperature
range
Altitude
Inclination
160
Measured in Standby: 32.1 dB
Regulation: 38 dB Max.
Measured in Printing: 55.8 dB
Regulation: 57 dB Max.
Operating: 20-80% RH (noncondensing)
Transportation/Storage: 10–90% RH (non-
condensing)
Operating: 50-90.5° F (10-32.5° C)
Transportation/Storage: 32-95° F (0-35° C)
Operating: 0-8202 ft (0-2500 m)
Operating: ±5° or less slant at any point around the
machine
80
70
60
50
40
30
20
10
0
10
50
Engine and Controller Specifications
Average
4 amperes
0.75 amperes
1.7 amperes
0.2 amperes
Optimal Operating Range
Acceptable Operating Range
17.5
20
63.5 68
Ambient Temperature
Maximum
8 amperes
4 amperes
8 amperes
4 amperes
32.5
30
27
80.6 86 95.0