Mounting an EX2300 Switch in a Recessed Position in a Rack or Cabinet

You can mount an EX2300 switch except the EX2300-C switch model on two posts or four posts of a
rack or cabinet such that the switch is recessed inside the rack from the rack front by 2 inches. You can
use the 2-in.-recess front-mounting brackets provided in the separately orderable four-post rack-mount
kit to mount the switch in a recessed position.
Reasons that you might want to mount the switch in a recessed position include:
• You are mounting the switch in a cabinet and the cabinet doors do not close completely unless the
switch is recessed.
• The switch you are mounting has transceivers installed in the uplink ports—the transceivers in the
uplink ports protrude from the front of the switch.
To mount the switch in a recessed position on four posts, follow the instructions in
EX2300 Switch on Four Posts of a Rack or Cabinet" on page
position on two posts, follow the instructions in
Cabinet" on page
113.

Connecting the EX2300 to Power

IN THIS SECTION

Connect Earth Ground to an EX Series Switch | 132

Connecting AC Power to an EX2300 Switch | 141
Connecting DC Power to an EX2300 Switch | 144
Connect Earth Ground to an EX Series Switch
IN THIS SECTION
Parts and Tools Required for Connecting an EX Series Switch to Earth Ground | 133
116. To mount the switch in a recessed
"Mounting an EX2300 Switch on Two Posts of a Rack or
"Mounting an
132

Hide quick links: