Advanced Topics
Using the Control Lines Connector
Figure 7-2
Switch Driver Circuit For Use With Control Lines Connector
C1_in
(from Control
Line Connector
on Test Set)
7 -8
+15 V
10 kΩ
12
13
1
16
9
8
5
4
-15 V
3
V
(from Power Supply)
C
2
14
10 V
15
11
10
6
7
Temic/Siliconix
DG413
Agilent Technologies Z5623A Option H48
C1_out
(to DUT)