Overview
network security key for each ZigBee®
communications from the network. In order to join the secured Air-Fi network, the network must first be
"opened" or set to allow devices to join. A device requesting to join the network is given a transport key
which must be decrypted by the joining device before it can communicate on the Air-Fi network. The Air-
Fi network will automatically close or prevent new devices from joining the network one hour after it was
opened.
Air-Fi® Device Part Numbers
The following table lists the Air-Fi® devices with their part numbers and indicates application conditions
and availability.
Table 2. Device application, availability, and part numbers
Air-Fi® device
Wireless communications interface (WCI)
Wireless communications sensor—Digital
display (WCS-SD)
Wireless communications sensor—Base
model (WCS-SB)
Wireless communications sensor accessory—2% relative humidity
sensor module (WCS-SH)
Wireless communications sensor— with
Occupancy sensor (WCS-SO)
Wireless communications sensor— with CO
and Occupancy sensors (WCS-SO/SCO
Wireless communications sensor - Base
model with external Refrigeration input
(WCS-SB/R)
(a)
BAA (Buy American Act)
(b)
1 setpoint, timed override, */**
(c)
1 setpoint, all Fan options, */**
(d)
2 setpoints, 2 Fan options (On-Auto), all System options (Off, Auto, Cool, Heat, Emergancy Heat)
Firmware Requirements for Devices on an Air-Fi® Network
The following table lists the minimum firmware levels required to allow devices to participate on an Air-Fi
network:
2.
ZigBee is a registered trademark of the ZigBee Alliance.
12
Application
Availability
Indoor
Outdoor
Field installed or
service
Indoor—BAA
(a)
Outdoor—BAA
Indoor flush
Service part only
Indoor
Factory only
Indoor flush
Universal
(b)
FC BC UV
(c)
and
RTU WSHP
offerings are factory
or service only (not
field applied)
RTU WSHP
(d)
Universal—BAA
(a)
Universal
Field, factory, or
Universal—BAA
(a)
service
Universal—BAA
(a)
2
Universal—BAA
(a)
)
2
Universal—BAA
(a)
network. This network security key is required to decrypt
2
Part number
X13790901030
X13790941030
X13790963030
X13790964030
X13790902030
X13790903030
X13790904030
X13790955010
X13790955040
X13790955050
X13790968010
X13790956010
X13790969010
X13790973030
X13790986001
X13790987001
X13791004001
Global part
BAYSENS
BAYWCII189A
MOD02969
BAYWCII187A
MOD02971
N/A
MOD03069
N/A
MOD03070
N/A
MOD02970
BAYWCII188A
N/A
N/A
N/A
N/A
SEN02362
N/A
SEN02394
BAYSENS202A
SEN02263
BAYSENS212A
SEN02265
BAYSENS203A
SEN02264
BAYSENS213A
SEN02266
BAYSENS230A
SEN02638
BAYSENS154A
SEN2502
BAYCO2K200A
SEN2503
N/A
SEN02773
BAS-SVX40K-EN