ITG Line 2.0/i2004 Internet Telephone Description, Installation, and Operation
Procedure 34
Configuring SNMP Traps
1
Return to the "MAT/OTM Navigator" window.
2
In the MAT/OTM Navigator window select Utilities | Alarm
Notification. The "MAT/OTM Alarm Notification" dialog box appears
(Figure 29).
3
Select Configuration | Run Options.
The "Alarm Notification Run Options" dialog box appears.
4
Click the Control Files tab.
5
Click Devices | Browse. The "Open" dialog box appears.
6
Select the "Devices.txt" file from the "Control Files" folder and click
Open. The "Devices.txt" file opens.
7
For each ITG Line 2.0 card in each monitored ITG Line 2.0 card node,
add a line consisting of three fields separated by spaces, as shown in
Table 28. Enter the first line under the last line that begins with a "#".
8
Click File|Save.
9
In the "Alarm Notification Run Options" window, click Apply then OK.
Note: MAT/OTM Alarm Notification must be restarted whenever
Control Files are changed.
10
If MAT/OTM Alarm Notification is running (i.e., the red traffic light is
showing on the tool bar), first stop it by clicking on the red traffic light
on the tool bar. Restart it by clicking on the green traffic light.
11
If MAT/OTM Alarm Notification is not running (i.e., green traffic light
showing on the tool bar), start it by clicking on the green traffic light to
change it to red.
12
Enter the trap_gen command from the ITG shell. A series of SNMP
traps is emitted by the ITG Line 2.0 card and appears in the MAT/OTM
Alarm Notification browser window. Verify the device name identifies
the correct ITG Line 2.0 card.
—————————— End of Procedure ——————————
ITG line card 2.0 administration
Page 185 of 302