Equipment and cable installation for 1665 Data Multiplexer
(1665 DMX)
Description
DS3#1-12 Cables with no BNC,
LNW16, LNW18 only
Similar to above except no BNC's
are shipped loose.
849040779 uses 735A cable, and
450ft is the maximum amount of
735A allowed between two DMX's
849041710 and lengths > 450ft use
~10ft 735A spliced to 734D cable
and 900ft is the maximum amount
of 734D allowed between two
DMX's. This splice is factory made.
Stagger the splices in the cable rack
to save space.
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 1, November 2007
DS3/EC1 and 48TMUX cable installation
Cable
Cable length
assembly #
(feet)
849040688
10
849040696
20
849040704
30
849040712
40
849040720
50
849040738
60
849040746
100
849040753
150
849040761
250
849040779
450
849041710
450
849041736
750
849041744
900
1665 DMX
backplane
connections
J1, J24 - J2, J20
(A OUT - A IN)
J3, J25 - J4, J21
(B OUT - B IN)
J6, J26 - J5, J22
(C OUT - C IN)
J8, J27 - J7, J23
(D OUT - D IN)