Installation tests
........................................................................................................................................................................................................................
Select Configuration -> Update System... -> Update All.
11
Requirement: The flashing FAULT LED should extinguish on the OC-12 OLIU.
There should be no alarm indications on the 1665 DMX shelf.
........................................................................................................................................................................................................................
Remove the 15-dB LBO from the OC-12 OLIU (Port 2).
12
........................................................................................................................................................................................................................
Replace all protective dust covers on the OC-12 OLIU connectors, that were removed to
13
perform this procedure.
........................................................................................................................................................................................................................
Repeat this entire procedure for each OC-12 OLIU in the 1665 DMX shelf.
14
........................................................................................................................................................................................................................
Check off the appropriate box in
15
E
O
N D
........................................................................................................................................................
OC-12 facility loopback testing
Facility Loopback testing allows the installer to verify cabling to the OC-12 equipment.
This test is only required if the 1665 DMX shelf is connected to OC-12 equipment. If the
shelf is NOT connected to OC-12 equipment, skip this section and continue to the section
on
OC-48 low-speed testing procedure (p.
Important!
are necessary for the testing.
The Function Unit slot under test must contain a OC-12 (LNW46) circuit pack in order to
perform this test.
........................................................................................................................................................................................................................
Log on to the 1665 DMX shelf using the CIT software as described in the
1
"Software download and circuit pack
(p.
3-9).
........................................................................................................................................................................................................................
Select Configuration -> Cross-Connections...
2
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 1, November 2007
S
F
T E P S
An optical test set with the capability to transmit OC-12 SONET levels
Appendix E, "Installation
4-52).
installation",
"Use of WaveStar
OC-12 (low-speed) testing
checklist".
Chapter 3,
®
CIT software"