Cable Lengths (Feet) - Alcatel-Lucent 1665 Installation Manual

Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Installation tests
........................................................................................................................................................................................................................
If a change is made click Apply.
6
........................................................................................................................................................................................................................
Repeat
7
populated with DS1 circuit packs.
........................................................................................................................................................................................................................
Check off the appropriate box in
8
E
O
N D
........................................................................................................................................................
Setting DS3/EC1 and TMUX LBOs
The DS3/EC1 and TMUX cabling will be tested with all ports provisioned for DS3. Set
DS3 LBO values as follows.
........................................................................................................................................................................................................................
Refer to the following table of cable lengths and LBO values. Determine the LBO value
1
corresponding to the DS3 (TMUX) cables installed:
Table 4-1
LBO Value
IN
OUT
........................................................................................................................................................................................................................
From the CIT GUI, select Configuration -> Equipment...
2
........................................................................................................................................................................................................................
Select the desired DS3 port by clicking the + sign next to the CP.
3
........................................................................................................................................................................................................................
Highlight the port and click Select.
4
........................................................................................................................................................................................................................
Next to Line Build Out: choose the LBO value determined in
5
........................................................................................................................................................................................................................
Repeat
6
with DS3 or TMUX circuit packs.
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 1, November 2007
Step 2
through
Step 6
S
F
T E P S

Cable lengths (feet)

734D
0 - 225
225-450
Step 1
through
Step 5
for all DS1 ports in all function unit slots which are
Appendix E, "Installation
735A
0-125
125-250
for all DS3 ports in all function unit slots that are populated
LBO software settings
checklist".
Step
1.
4 - 5