Installation tests
........................................................................................................................................................................................................................
Select Fault -> Analysis -> Loopback...
1
........................................................................................................................................................................................................................
Choose the DS1 port to test and click Select.
2
........................................................................................................................................................................................................................
Select Operate and Loopback Type: Facility and click Apply.
3
........................................................................................................................................................................................................................
Once the loopback is up, a test signal shall be generated at the DS1 terminating equipment
4
which will verify that the cabling is correct.
Important!
loopback.
........................................................................................................................................................................................................................
Once the test is complete, remove the loopback.
5
Select Fault -> Analysis -> Loopback...
........................................................................................................................................................................................................................
Choose the DS1 port to test and click Select.
6
........................................................................................................................................................................................................................
Select Release and Loopback Type: Facility and click Apply.
7
........................................................................................................................................................................................................................
8
Repeat
........................................................................................................................................................................................................................
Check off the appropriate box in
9
E
O
N D
........................................................................................................................................................
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 1, November 2007
A test set can be applied at the DSX-1 to test cabling toward the facility
Step 1
through
Step 7
S
F
T E P S
for each DS1 cabled to the DSX-1.
Appendix E, "Installation
Local equipment and cross-connect tests
checklist".