Ring setup and testing: integration procedures
Important!
directions to make up the ring. At each shelf (node) in the ring, the M1 OLIU will
connect to the M2 OLIU in one adjacent node, and the M2 OLIU will connect to the
M1 OLIU in the other adjacent node. Likewise, when the 1665 DMX is interfacing
with other equipment at low-speeds (OC-3, OC-12 or OC-48) using 0x1 protection,
the Function Group slot (A, B, C, D, or G) 1 will connect to Main 2 on whatever shelf
the 1665 DMX is being connected to. The Function Group slot (A, B, C, D, or G) 2
will connect to Main 1.
........................................................................................................................................................................................................................
At each end of the optical span, connect the optical fiber transmit cables to the OLIU OUT
10
connectors.
........................................................................................................................................................................................................................
At each end of the optical span, measure the optical power of the optical fiber receive
11
cables using an optical power meter.
........................................................................................................................................................................................................................
Determine the LBO value required based on the received optical power measurement.
12
Refer to the following table.
Table 6-1
............................................................................................................................................................................................................................................................
6 - 6
For 1665 DMX ring configurations, optical fibers extend in two different

Attenuation Table

Optics
Circuit Pack
OC-48 (High
LNW27
Speed)
LNW29
LNW221 - 259
LNW421 - 459
LNW32
LNW76
Low-Speed
LNW36 (OC-3)
Optics (OC-3,
OC-12, OC-48)
LNW46 (OC-12)
LNW31 (OC-48)
Fiber installation
Received
LBO
Power (dBM)
(dB)
+3.0 to -9.0
15
-9.0 to -29.0
0
-3.0 to -18.0
0
0.0 to -15.0
10
-15.0 to -34.0
0
+2.0 to -8.0
10
-8.0 to -15.0
5
-15.0 to -30.5
0
0.0 to -18.0
0
Issue 1, November 2007
365-372-304R7.1