28 February '91
9.11 DRUM LOCK SOLENOID ADJUSTMENT:
VT2300/VT2500
Solenoid OFF
Purpose : To prevent the drum unit from being removed when it is not at the
original drum position.
1. Install the drum unit in the machine.
2. Access I/O check mode (See page 4-11).
Enter "0" in the memory display and "34" in the copy counter.
3. Press the Print Start key to turn on the drum lock solenoid [A].
4. Make sure that the drum lock arm [B] and the stopper [C] are no further
than 0.3 mm apart when the solenoid turns on.
5. If the drum and the stopper are too far apart, loosen the 2 screws [D] and
adjust the drum lock solenoid position.
0 ~ 0.3 mm
Solenoid ON
[B]
[C]
5-70
[A]
[D]