2.2 ORIGINAL PRESSURE SOLENOID ADJUSTMENT:
VT2300/VT2500
[E]
[A]
Purpose: To ensure that the originals are separated properly.
1. Remove the screw securing the stopper [A].
2. Remove the platen plate [B] (2 screws).
3. Remove the original guide [C] (4 screws).
4. Remove the ADF unit cover [D] (5 screws).
5. Unhook the both hook springs [E].
6. Remove the separation guide plate [F] (4 screws).
7. Adjust the original pressure solenoid [G] position so that the space
between the E-ring and the rubber cushion is 6.0 to 6.5 mm when the
solenoid is turned off.
[D]
[C]
5-4
6.0 -- 6.5 mm
[E]
[G]
[B]
[F]