6. MASTER EJECT SECTION
6.1 MASTER EJECT SOLENOID ADJUSTMENT
Purpose:
To ensure that master is ejected.
1. Open the master eject unit and remove the upper cover of the master eject unit
(4 screws).
2. Access I/O check mode (See page 4-11), and eEnter "0" in the memory display
and "7" in the copy counter.
3. Press the Print Start key to turn on the master eject solenoid.
4. Confirm that the lower first eject rollers [A] are touched to the drum surface and
also confirm that they are separated from the drum when the master eject
solenoid turns off.
5. If it is out of adjustment, loosen the screws [B] and adjust the mounting position
of the master eject solenoid [C].
6. After adjustment, retighten the screws [B].
NOTE:
To easily confirm whether the lower roller touches to the drum surface.
Wrap the drum with the blank paper. Check the paper for roller marks.
[C]
[B]
5-31
28 February '91
[C]
[A]