9.6 MASTER EJECT CLAMPER CAM ADJUSTMENT
Purpose: To position the master eject clamper cam so that the master
clamper opens correctly during the master eject process and
closes correctly for all other processes.
1. Remove the drum unit from the machine and open the master eject unit.
2. Remove the rear cover of the machine.
3. Access I/O check mode (See page 4-11).
Enter "0" in the memory display and "8" in the copy counter.
4. Press the Print Start key to turn on the master eject clamper solenoid [A].
5. Make sure that the distance between the bushing and the edge of the
opening cam [B] is 29 ± 0.5 mm when the master eject clamper solenoid
turns on.
6. If not, loosen the mounting screws [C] and adjust the position of the
master eject clamper solenoid.
CAUTION: Do not turn on the solenoid any longer than 10 seconds.
5. After adjustment, retighten the mounting screws.
[C]
ON= 29±0.5 mm
[B]
OFF= less than 25 mm
5-65
28 February '91
[A]
[B]