5.6 MASTER BUCKLE SENSOR REPLACEMENT
1. Turn off the main switch.
2. Slide the scanner unit to the left.
3. Remove the master roll.
4. Remove the cutter unit [A] (2 screws).
5. Disconnect the buckle sensor connector [B].
6. Remove the buckle sensor [C] together with the bracket [D] (2 screws).
7. Remove the buckle sensor from the bracket (2 screws).
[B]
[C]
[A]
[D]