CIO n+49 (Setting)
The device variables for CJ-series Units that correspond to bits 00 to 15 in CIO n+49 are listed in the
following table.
CJ-series I/O memory address
Word address
CIO n+49
CIO n+50 to CIO n+53 (WORD OUT Connect Flags/Communication Error
Flags) and (WORD IN Connect Flags/Communication Error Flags)
The device variables for CJ-series Units that correspond to bits 00 to 15 in CIO n+50 to CIO n+53
are listed in the following table.
CJ-series I/O memory address
Word address
CIO n+50
CIO n+51
CIO n+52
CIO n+53
CJ-series CompoNet Master Unit Operation Manual for NJ-series CPU Unit (Cat. No. W493)
Device variable for CJ-series Unit in the NJ-series CPU Unit
Bit number
Variable
0 to 15
*_UnitCmd
0
*_IOCycleStartCmd
1 to 15
---
Device variable for CJ-series Unit in the NJ-series CPU Unit
Bit number
Variable
0 to 7
*_OutCnctNdSta00_07
0
*_OutCnctNdSta00
:
:
7
*_OutCnctNdSta07
8 to 15
*_OutErrNdSta00_07
8
*_OutErrNdSta00
:
:
15
*_OutErrNdSta07
0 to 7
*_InCnctNdSta00_07
0
*_InCnctNdSta00
:
:
7
*_InCnctNdSta07
8 to 15
*_InErrNdSta00_07
8
*_InErrNdSta00
:
:
15
*_InErrNdSta07
0 to 7
*_OutCnctNdSta08_15
0
*_OutCnctNdSta08
:
:
7
*_OutCnctNdSta15
8 to 15
*_OutErrNdSta08_15
8
*_OutErrNdSta08
:
:
15
*_OutErrNdSta15
0 to 7
*_InCnctNdSta08_15
0
*_InCnctNdSta08
:
:
7
*_InCnctNdSta15
8 to 15
*_InErrNdSta08_15
8
*_InErrNdSta08
:
:
15
*_InErrNdSta15
Name
Setting
Remote I/O Communications Start Switch
Reserved
Name
WORD OUT Connect Flag(00 to 07)
WORD OUT Connect Flag00
:
WORD OUT Connect Flag07
WORD OUT Communication Error Flag(00 to 07)
WORD OUT Communication Error Flag00
:
WORD OUT Communication Error Flag07
WORD IN Connect Flag(00 to 07)
WORD IN Connect Flag00
:
WORD IN Connect Flag07
WORD IN Communication Error Flag(00 to 07)
WORD IN Communication Error Flag00
:
WORD IN Communication Error Flag07
WORD OUT Connect Flag(08 to 15)
WORD OUT Connect Flag08
:
WORD OUT Connect Flag15
WORD OUT Communication Error Flag(08 to 15)
WORD OUT Communication Error Flag08
:
WORD OUT Communication Error Flag15
WORD IN Connect Flag(08 to 15)
WORD IN Connect Flag00
:
WORD IN Connect Flag15
WORD IN Communication Error Flag(08 to 15)
WORD IN Communication Error Flag08
:
WORD IN Communication Error Flag15