Omron CJ Series Operation Manual page 190

Machine automation controller
Hide thumbs Also See for CJ Series:
Table of Contents

Advertisement

5 Remote I/O Communications
I/O Port Allocation Pattern for each Communications Mode
Communications
mode number
0
1
5-38
Device variables for the CJ-series
Unit
*_OutDat00 to *_OutDat07
((*_OutDat00_00 to *_OutDat00_15)
to (*_OutDat07_00 to
*_OutDat07_15))
*_InDat00 to *_InDat07
(*_InDat00_00 to *_InDat00_15 to
*_InDat07_00 to *_InDat07_15)
*_UnitSta
*_UnitCmd
*_OutCnctNdSta00_07
(*_OutCnctNdSta00 to 07)
*_InCnctNdSta00_07
(*_InCnctNdSta00 to 07)
*_OutErrNdSta00_07
(*_OutErrNdSta00 to 07)
*_InErrNdSta00_07
(*_InErrNdSta00 to 07)
Device variables for the CJ-series
Unit
*_OutDat00 to *_OutDat15
((*_OutDat00_00 to *_OutDat00_15)
to (*_OutDat15_00 to
*_OutDat15_15))
*_InDat00 to *_InDat15
((*_InDat00_00 to *_InDat00_15) to
(*_InDat15_00 to *_InDat15_15))
*_UnitSta
*_UnitCmd
*_OutCnctNdSta00_07
(*_OutCnctNdSta00 to 07)
*_OutCnctNdSta08_15
(*_OutCnctNdSta08 to 15)
*_InCnctNdSta00_07
(*_InCnctNdSta00 to 07)
*_InCnctNdSta08_15
(*_InCnctNdSta08 to 15)
*_OutErrNdSta00_07
(*_OutErrNdSta00 to 07)
*_OutErrNdSta08_15
(*_OutErrNdSta08 to 15)
*_InErrNdSta00_07
(*_InErrNdSta00 to 07)
*_InErrNdSta08_15
(*_InErrNdSta08 to 15)
CJ-series CompoNet Master Unit Operation Manual for NJ-series CPU Unit (Cat. No. W493)
Pattern
Slave Unit I/O data
WORD OUT Data (8 words): Word Slave Unit outputs 00
to 07
WORD IN Data (8 words): Word Slave Unit inputs 00 to
07
Status (1 word)
Setting (1 word)
WORD OUT Connect Flags (BYTE): Word
Slave outputs 00 to 07
WORD IN Connect Flags (BYTE): Word Slave
Unit inputs 00 to 07
WORD OUT Communication Error Flags
(BYTE): Word Slave outputs 00 to 07
WORD IN Communication Error Flags
(BYTE): Word Slave Unit inputs 00 to 07
Slave Unit I/O data
WORD OUT Data (16 words): Word Slave Unit outputs
00 to 15
WORD IN Data (16 words): Word Slave Unit inputs 00 to
15
Status (1 word)
Setting (1 word)
WORD OUT Connect Flags:
Word Slave Unit outputs 00 to 07 (BYTE)
Word Slave Unit outputs 08 to 15 (BYTE)
WORD IN Connect Flags:
Word Slave Unit inputs 00 to 07 (BYTE)
Word Slave Unit inputs 08 to 15 (BYTE)
WORD OUT Communication Error Flags:
Word Slave Unit outputs 00 to 07 (BYTE)
Word Slave Unit outputs 08 to 15 (BYTE)
WORD IN Communication Error Flags:
Word Slave Unit inputs 00 to 07 (BYTE)
Word Slave Unit inputs 08 to 15 (BYTE)
(1
word)
(1
word)
(1
word)
(1
word)
(1
word)
(1
word)