Omron CJ Series Operation Manual page 179

Machine automation controller
Hide thumbs Also See for CJ Series:
Table of Contents

Advertisement

Device variables for the
CJ-series Unit
*_BitOutCnctNdSta32_39
*_BitOutCnctNdSta32
to
*_BitOutCnctNdSta39
*_BitOutCnctNdSta40_47
*_BitOutCnctNdSta40
to
*_BitOutCnctNdSta47
*_BitOutCnctNdSta48_55
*_BitOutCnctNdSta48
to
*_BitOutCnctNdSta55
*_BitOutCnctNdSta56_63
*_BitOutCnctNdSta56
to
*_BitOutCnctNdSta63
Connect Flags for Bit Input Slaves (Communications Mode Number
3)
These variables can be used only with the communications mode number is set to 3.
Device variables for the
CJ-series Unit
*_BitInCnctNdSta00_07
*_BitInCnctNdSta00
to
*_BitInCnctNdSta07
*_BitInCnctNdSta08_15
*_BitInCnctNdSta08
to
*_BitInCnctNdSta15
*_BitInCnctNdSta16_23
*_BitInCnctNdSta16
to
*_BitInCnctNdSta23
*_BitInCnctNdSta24_31
*_BitInCnctNdSta24
to
*_BitInCnctNdSta31
*_BitInCnctNdSta32_39
*_BitInCnctNdSta32
to
*_BitInCnctNdSta39
*_BitInCnctNdSta40_47
*_BitInCnctNdSta40
to
*_BitInCnctNdSta47
CJ-series CompoNet Master Unit Operation Manual for NJ-series CPU Unit (Cat. No. W493)
Data
R/W
type
BYTE
R
BIT OUT Connect Flag32_39
BOOL
R
BIT OUT Connect Flag32
BIT OUT Connect Flag39
BYTE
R
BIT OUT Connect Flag40_47
BOOL
R
BIT OUT Connect Flag40
BIT OUT Connect Flag47
BYTE
R
BIT OUT Connect Flag48_55
BOOL
R
BIT OUT Connect Flag48
BIT OUT Connect Flag55
BYTE
R
BIT OUT Connect Flag56_63
BOOL
R
BIT OUT Connect Flag56
BIT OUT Connect Flag63
Data
R/W
type
BYTE
R
BIT IN Connect Flag00_07
BOOL
R
BIT IN Connect Flag00
BIT IN Connect Flag07
BYTE
R
BIT IN Connect Flag08_15
BOOL
R
BIT IN Connect Flag08
BIT IN Connect Flag15
BYTE
R
BIT IN Connect Flag16_23
BOOL
R
BIT IN Connect Flag16
BIT IN Connect Flag23
BYTE
R
BIT IN Connect Flag24_31
BOOL
R
BIT IN Connect Flag24
BIT IN Connect Flag31
BYTE
R
BIT IN Connect Flag32_39
BOOL
R
BIT IN Connect Flag32
BIT IN Connect Flag39
BYTE
R
BIT IN Connect Flag40_47
BOOL
R
BIT IN Connect Flag40
BIT IN Connect Flag47
5 Remote I/O Communications
Name
Bits 0 to 7: Bit node addresses 32 to 39
BIT OUT Connect Flags for bit node
addresses 32 to 39
to
Bits 0 to 7: Bit node addresses 40 to 47
BIT OUT Connect Flags for bit node
addresses 40 to 47
to
Bits 0 to 7: Bit node addresses 48 to 55
BIT OUT Connect Flags for bit node
addresses 48 to 55
to
Bits 0 to 7: Bit node addresses 56 to 63
BIT OUT Connect Flags for bit node
addresses 56 to 63
to
Name
Bits 0 to 7: Bit node addresses 00 to 07
BIT IN Connect Flags for bit node
addresses 00 to 07
to
Bits 0 to 7: Bit node addresses 08 to 15
BIT IN Connect Flags for bit node
addresses 08 to 15
to
Bits 0 to 7: Bit node addresses 16 to 23
BIT IN Connect Flags for bit node
addresses 16 to 23
to
Bits 0 to 7: Bit node addresses 24 to 31
BIT IN Connect Flags for bit node
addresses 24 to 31
to
Bits 0 to 7: Bit node addresses 32 to 39
BIT IN Connect Flags for bit node
addresses 32 to 39
to
Bits 0 to 7: Bit node addresses 40 to 47
BIT IN Connect Flags for bit node
addresses 40 to 47
to
Description
Description
5-27
5

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Nj seriesCj1w-crm21

Table of Contents