CIO n+32 (Status)
The device variables for CJ-series Units that correspond to bits 00 to 15 in CIO n+32 are listed in the
following table.
CJ-series I/O memory address
Word address
CIO n+32
CIO n+33 (Setting)
The device variables for CJ-series Units that correspond to bits 00 to 15 in CIO n+33 are listed in the
following table.
CJ-series I/O memory address
Word address
CIO n+33
CIO n+34 to CIO n+37 (WORD OUT Connect Flags/Communication Error
Flags) and (WORD IN Connect Flags/Communication Error Flags)
The device variables for CJ-series Units that correspond to bits 00 to 15 in CIO n+34 to CIO n+37
are listed in the following table.
CJ-series I/O memory address
Word address
CIO n+34
CJ-series CompoNet Master Unit Operation Manual for NJ-series CPU Unit (Cat. No. W493)
Device variable for CJ-series Unit in the NJ-series CPU Unit
Bit number
Variable
0 to 15
*_UnitSta
0
*_SlavCommErr
1
*_RegTblErr
2
*_CommStopSta
3
*_SlavDupErr
4
*_RepeaterCommErr
5
*_RepeaterDupAdrErr
6
*_SlavAllCnctSta
7
*_IOCycleStartSta
8
*_PLCRunSta
9
---
10
*_RegTblSta
11
---
12
*_SlavAllWarnSta
13
*_SlavAllAlmSta
14
---
15
---
Device variable for CJ-series Unit in the NJ-series CPU Unit
Bit number
Variable
0 to 15
*_UnitCmd
0
*_IOCycleStartCmd
1 to 15
---
Device variable for CJ-series Unit in the NJ-series CPU Unit
Bit number
Variable
0 to 7
*_OutCnctNdSta00_07
0
*_OutCnctNdSta00
:
:
7
*_OutCnctNdSta07
8 to 15
*_OutErrNdSta00_07
8
*_OutErrNdSta00
:
:
15
*_OutErrNdSta07
Name
Status
Communications Error Flag
Registration Table Verification Error Flag
Communications Error Communications Stop Flag
Slave Unit Duplicated Address Error Flag
Repeater Unit Communications Error Flag
Repeater Unit Node Slave Unit Duplicated
Address Error Flag
All Registered Slave Units Participating Flag
Remote I/O Communications Started Flag
Ladder Operation Allowed Flag in Registration
Table Enabled Mode
Reserved
Registration Table Mode Flag
Reserved
Representative Warning Status Flag
Representative Alarm Status Flag
Reserved
Reserved
Name
Setting
Remote I/O Communications Start Switch
Reserved
Name
WORD OUT Connect Flag(00 to 07)
WORD OUT Connect Flag00
:
WORD OUT Connect Flag07
WORD OUT Communication Error Flag(00 to 07)
WORD OUT Communication Error Flag00
:
WORD OUT Communication Error Flag07