Procedure; Pressure Relief Procedure - Graco HydroShield WABH00 Instructions - Parts Manual

Automatic air-assisted batch waterborne isolation systems
Table of Contents

Advertisement

Operation
Pressure Relief
Relief Procedure

Procedure

Pressure
Pressure
Relief
Procedure
Follow the Pressure Relief
Procedure whenever you see this
symbol.
This equipment stays pressurized until pressure
is manually relieved. To help prevent serious
injury from pressurized fluid, such as skin injection,
splashing fluid, and moving parts, follow the
Pressure Relief
Relief Procedure
Procedure when you stop spraying
Pressure
Pressure
Relief
Procedure
and before cleaning, checking, or servicing the
equipment.
1. Release the gun trigger and turn off electrostatics
by disabling the electrostatic request signal.
2. Follow the
Fluid Voltage Discharge and
Grounding Procedure, page
3. Push the Stop button
interface to change to Off mode. See
Control Interface, page
4. Turn off the air supply and fluid supply to the
system.
5. Trigger the gun into a grounded metal waste
container to relieve the fluid pressure in the gun,
the gun fluid hose, and the fluid pump in the
isolation system
30
29.
on the control
36.
6. Relieve fluid pressure in the fluid supply unit as
instructed in your fluid supply unit manual.
7. If the objective is to shut down and then service
the system, relieve any residual pressure in the
two flexible fluid lines between the inlet valves (J)
and the isolation fluid pump (K).
Note
The contents of the isolation fluid pump
(K) may spill into the cabinet at this
point. If the pump has been emptied, the
volume of fluid in the lines is small and
only a small amount of fluid may spill out.
a. To relieve the fluid pressure between the
fluid valve (J) and the isolation valve (G),
carefully loosen one of the swivel fittings.
b. To relieve the fluid pressure between the
isolation valve (G) and the isolation fluid
pump (K), carefully loosen one of the swivel
fittings.
3A8492A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hydroshield wabh02

Table of Contents