Connect The Hoses - Graco HydroShield WABH00 Instructions - Parts Manual

Automatic air-assisted batch waterborne isolation systems
Table of Contents

Advertisement

All solvent pails:
Use only grounded metal
containers, which are conductive. Do not use
plastic containers. Use only non-flammable
solvents. Do not store more than the quantity
needed for one shift.
• All persons entering the spray area must wear
shoes having conductive soles such as leather,
or wear personal grounding straps. Do not wear
shoes with non-conductive soles such as rubber
or plastic.
3A8492A
Connect the
the Hoses
Hoses
Connect
Connect
the
Hoses
To reduce the risk of electric shock, install only
one continuous Graco waterborne hose between
the isolation cabinet and the gun. Do not splice
hoses together.
Always use a Graco waterborne fluid hose between
the fluid outlet on the isolation cabinet and the
gun fluid inlet. If using multiple guns make sure
the hose connections are electrically isolated and
properly discharged before any maintenance is
performed.
If using multiple guns or a remote mounted fluid
regulator then make sure the hose connections are
electrically isolated and properly discharged before
any maintenance is performed.
When setting up the isolation system for the first time,
connect the hoses in the following order:
1. Fluid hose from the gun to the isolation cabinet.
See
Connect the Fluid Hose from the Gun to the
Cabinet, page
18.
2. Air hose from the air supply to the isolation
cabinet. See .
3. Fluid hose from the fluid supply to the isolation
cabinet. See
Connect the Fluid Supply Hose to
the Cabinet, page
22.
Note
• If the fluid hose must pass through the
wall of a booth to the isolation cabinet,
make sure that the hole through the booth
wall does not have sharp edges that could
damage the hose.
• The holes in the wall must be large enough
to allow the hose fittings to pass through.
Installation
17