Run Menus

Events Screen

Screen
Events
Events
Screen
Use the Events screen to view the last 99 status
messages generated by the isolation system. Click
the up and down arrows on the right of the screen to
scroll through the messages.
Each message line includes the date, the time, and
the status code. See
Error Codes, page

Status Screens

Screens
Status
Status
Screens
The Status screens display a summary of the input
signals that are monitored by the system and the
solenoids that drive system activity. The screens are
for information and troubleshooting purposes.
Status
Status Screen
Status
Screen 1 1 1
Screen
The Status screens display a summary of the input
signals that are monitored by the system and the
solenoids that drive system activity. The Status
screens are for information and troubleshooting
purposes.
Inputs
Inputs
Inputs
50
Inputs are signals that the system acts on. When the
status circle next to the input appears yellow, the
sensor is activated.
System Stop:
• System
System
that tells the system to stop. The system stop
pneumatic input is available only when the optional
System Stop Pneumatic Input Kit 26B414 is
installed. To install, see
81.
Stop Pneumatic Input Kit, page
• System
System Stop:
System
that tells the system to stop. The system stop
digital input is available only when the optional
Optocoupler Kit 24Z226 is installed. To install, see
Install the Optional System Status Output, page
• Inlet
Inlet Air:
Inlet
pressure 70 psi (0.5 MPa, 4.8 bar) is detected.
• Shuttle
Shuttle
Shuttle Top:
isolation valve is in the top position.
Shuttle Bottom:
• Shuttle
Shuttle
isolation valve is in the bottom position.
• Gun
Gun Flush
Gun
gun flush box is closed. Not used on automatic
systems.
• Fluid
Fluid Trigger:
Fluid
that the gun is triggered. Not used on automatic
systems.
Solenoids
Solenoids
Solenoids
Electrical to pneumatic actuators that drive system
activity.
• Shuttle
Shuttle
Shuttle Down:
open for filling.
Shuttle Up:
• Shuttle
Shuttle
closed for isolating the charged fluid.
• Shuttle
Shuttle
Shuttle Eject:
isolation valve up from the seat.
Shuttle Fluid
• Shuttle
Shuttle
system fluid inlet.
• Pump
Pump
Pump Fluid
isolation fluid pump fluid inlet when it is present.
This fluid valve is not present in standard systems.
Purchase a conversion kit to replace a spring
check valve with a pneumatically activated fluid
inlet valve.
• Pump
Pump
Pump Pressure:
isolation fluid pump.
Ground Rod:
• Ground
Ground
allow the system to build a charge.
• Gun
Gun Flush
Gun
gun flush box. Not used on automatic systems.
• System
System
System Status:
okay to spray.
Stop: Air:
Air: The external pneumatic input
Stop:
Air:
Install the Optional System
Stop: Digital:
Stop:
Digital: The external electrical input
Digital:
Air: Indicates the minimum required air
Air:
Top: The sensor that indicates that the
Top:
Bottom: The sensor that indicates that the
Bottom:
Flush Box:
Flush
Box: The sensor that indicates that the
Box:
Trigger: The air flow switch that indicates
Trigger:
Down:
Down: Drives the isolation valve down and
Up: Drives the isolation valve up and
Up:
Eject: From the down position, ejects the
Eject:
Fluid In:
In: Opens the fluid valve near the
Fluid
In:
Fluid In:
Fluid
In: Opens the fluid valve near the
In:
Pressure: Activates the air pressure to the
Pressure:
Rod: Activates (raises) the ground rod to
Rod:
Flush Box:
Flush
Box:
Box: Activates the gun trigger in the
Status:
Status: Indicates to the system that it is