6. Use an ohmmeter (or megohmmeter in the ohm
range) to measure the resistance between the
cabinet ground lug (214) and a true earth ground
(CC). The resistance must be less than 100
ohms.
Figure 20 Check the Grounding of the Cabinet
28
Flush the
the Equipment
Equipment Before
Flush
Flush
the
Equipment
The equipment was tested in fluid at the factory. To
avoid contaminating your fluid, flush the equipment
with flushing fluid before you use the equipment. See
Flush the System (Systems without Color Change),
page 31