1. Prepare the isolation system for service. See
Prepare the Isolation System for Service, page
90.
2. Use a flat blade screwdriver to open the isolation
cabinet door.
3. Slide the electrostatic shield (82) up to remove.
4. To remove the isolation valve cover (99), loosen
the top and bottom screws (99a).
5. Remove the four 3/16 inch hex head screws to
open the electronics panel (14).
6. Locate the wire from the pump sensor into the
electronics panel. Disconnect the pump sensor
(321) from the cable splitter (447). For wiring
locations, see
Wiring Connections, page
Figure 44 Pump Sensor Connection in
Electronics Panel
7. Disconnect the air line from the air fitting (325).
3A8492A
Fluid Pump
Pump
Fluid
Pump
Fluid Pump
Fluid
Pump from
Pump
from the
from
the
the
112.
8. Remove the two fluid tubes from the fittings (327)
at the base of the pump. Some residual fluid
may leak out.
9. A steel bracket (17) holds the pump. To remove
the pump, either:
• Remove the two screws that hold the bracket
to the back wall of the cabinet. Use a 3/16 inch
socket cap hex head wrench and extension.
• Remove the two screws that hold the bracket
to the pump. Use a 7/16 inch hex head wrench.
10. Remove the two base mounting screws (20), lock
washers (22), and washers (19).
11. Lift the pump out of the cabinet.
Figure 45 Remove the Isolation Fluid Pump
Repair
101