Repair
Service the
the Electrical
Electrical Controls
Service
Service
the
Electrical
Use the procedures in this section to service
components of the electrical controls as
needed. The procedures refer to the figures in
Electrical Schematics, page
Prepare the
the Electrical
Electrical Controls
Prepare
Prepare
the
Electrical
1. Prepare the isolation system for service. Follow
of the steps in
Prepare the Isolation System for
Service, page
90.
2. Remove power from the isolation system.
3. Use a flat blade screwdriver to open the isolation
cabinet door.
4. Loosen the cover screws (416) and remove the
cover (402).
5. Open the electrical control assembly.
Replace a a a Solenoid
Solenoid Valve
Replace
Replace
Solenoid
1. Prepare the electrical controls for service. Follow
the steps in
Prepare the Electrical Controls for
Service, page
106.
2. Remove the connector (433) from the color
change board (403).
3. Disconnect the solenoid wire.
4. Remove the solenoid valve (407) from the
manifold (406) by turning it counter clockwise.
5. Install a new solenoid. Lubricate the o-ring.
6. Reconnect the solenoid wire to connector
(433). Reinstall connector (433) on the color
change board (403). For location details, see
Electrical Schematics, page
7. Use Maintenance screens 3-6 to verify the
operation of the solenoid.
106
Controls
Controls
109.
Controls for
for Service
Service
Controls
for
Service
Valve
Valve
109.
Replace
Replace a a a kV
Replace
kV
kV Board
Board
Board
1. Prepare the electrical controls for service. Follow
the steps in
Prepare the Electrical Controls for
Service, page
106.
2. Disconnect the wires from the kV board assembly
(428).
3. Pull the tab with a screw driver to release the
board from the DIN rail (436).
4. Install a new kV board assembly.
5. Snap the board on the DIN rail (436).
6. Reconnect the cable (445) as shown in
Electrical Schematics, page
7. Connect the wires to the kV board as shown in
Electrical Schematics, page
109.