Graco HydroShield WABH00 Instructions - Parts Manual page 19

Automatic air-assisted batch waterborne isolation systems
Table of Contents

Advertisement

Connect
Connect the
Connect
the Paint
the
Paint Trigger
Paint
Trigger Input
Trigger
The system relies on a pneumatic paint trigger signal
to know when to dispense paint. When the paint
trigger signal is removed it knows it can begin the
refill process.
1. Tap into the paint trigger air line going to the
spray gun.
2. Run a 5/32" air line from the spray gun's paint
trigger line to the HydroShield.
3. Plug the 5/32" air line into the paint trigger input
(PTI) port on the right side of the system.
Figure 10 Air Line Connections
3A8492A
Input
Input
Connect the
Connect
Connect
the
the Electrostatic
Electrostatic Request
Electrostatic
The system needs to know when the use of
electrostatics is desired. With this signal the system
will confirm the request and enable an electrostatic
output if Spray mode is active. Connect the signal
that would normally enable electrostatics to this input.
There are pneumatic and electrical options for this
input.
Pneumatic Input
Pneumatic
Pneumatic
Input
Input
1. Connect a 5/32" air line to the electrostatic
request input (ERI) port as shown in
Connect the Paint Trigger Input, page
2. Supply air pressure above 70 psi (.48 MPa, 4.8
bar) to activate the input.
Electrical Input
Input
Electrical
Electrical
Input
1. Prepare the electrical controls for service. Follow
the steps in
Prepare the Electrical Controls for
Service, page
106.
2. Run two wires through the I/O port strain relief on
the right side of the system.
Figure 11 I/O Ports
3. Feed these wires through the top right opening
in the electronics control panel.
Installation
Request Input
Request
Input
Input
19.