Operation; Pressure Relief Procedure; Flushing - Graco 965660 Instructions And User Manual

Variable ratio mini-cat proportioner
Table of Contents

Advertisement

309239 Instructions - Parts List

Pressure Relief Procedure

Pressure Relief Procedure
Pressure Relief Procedure
Pressure Relief Procedure
Pressurized Equipment Hazard
The system pressure must be manually relieved to pre-
vent the system from starting or spraying accidentally.
To reduce the risk of an injury from accidental spray
from the gun, splashing fluid, or moving parts, follow
the Pressure Relief Procedure whenever you:
are instructed to relieve the pressure,
stop spraying,
check or service any of the system equipment,
or install or clean the spray nozzle.
1. Lock the spray gun safety latch.
2. Shut off the power source to the pump.
3. Close the bleed-type master air valve (required in
the system).
4. Unlock the spray gun safety latch.
5. Hold a metal part of the spray gun firmly to the side
of a grounded metal pail, and trigger the gun to
relieve fluid pressure.
6. Lock the spray gun safety latch.
7. Open the pressure relief valve, having a container
ready to catch the drainage. Leave the valve open
until you are ready to spray again.
8. If you suspect that the spray tip/nozzle or hose is
completely clogged or that pressure has not been
fully relieved after following the steps above, very
slowly loosen the tip guard retaining nut or hose end
coupling to relieve pressure gradually, then loosen
completely. Now clear the tip/nozzle or hose.

Operation

Operation
Operation
Operation
Operation
WARNING

Flushing

Flushing
Flushing
Flushing
To reduce the risk of fire, explosion, and serious injury
from static sparking and splashing, be sure to follow
these precautions before and during system flushing:
Be sure the entire system and flushing pails are
properly grounded. Refer to
page 10.
Wear eye protection.
Follow the "Pressure Relief Procedure" before
flushing and before removing a spray tip.
If a high pressure spray gun is being used, remove
the spray tip before flushing.
Use the lowest possible fluid pressure and maintain
firm metal-to-metal contact between the spray gun
and pail during flushing,
The pumps, mixer manifold and other components were
tested with lightweight oil at the factory. Before operat-
ing the pump, thoroughly flush the Mini-Cat system to
prevent contamination of your fluids. Follow the
ing the System
on page 14.
Flush the mixer, hose and gun often enough to prevent
fluid from reacting or curing in them. Contact your fluid
manufacturer for the effective pot life of the fluid you are
using.
WARNING
Ground the System
Flush-
on
13