Graco HydroShield WABH00 Instructions - Parts Manual page 47

Automatic air-assisted batch waterborne isolation systems
Table of Contents

Advertisement

Key or or or
Key
Key
Field
Field
Field
Description
Description
Description
Do Not
Do
Do
Not Fill
Not
Fill
Fill
Activate Do Not Fill to prevent the isolation fluid pump from refilling when the trigger is released
and the ES request signal is disabled. Do Not Fill is commonly used at the end of a paint job.
Once the pump is empty, the system waits until another mode is selected.
Do Not Fill mode is useful in the following situations:
While in Spray mode:
• The operator is getting close to the end of the shift and doesn't want paint to sit in the pump.
• The remaining number of parts to spray won't require another full pump of paint.
• The paint color will be changing soon.
While in Purge mode (without color change enabled):
• The operator is done spraying and is dispensing the last of the paint in the pump through the gun.
Once the pump is empty, the operator can easily switch the fluid supply hose to cleaning fluid.
Inlet air
air
Inlet
Inlet
air
A green inlet air status bar indicates the inlet air supply pressure is above the minimum required
70 psi (0.5 MPa, 4.8 bar).
Red indicates the system cannot run because the required air pressure is not detected.
Ground rod
rod
Ground
Ground
rod
A ground rod icon indicates that the ground rod (N) is down and the system is discharging.
A charge icon
Volt Level
Level
Volt
Volt
Level
Displays the system voltage level.
Fluid Level
Level
Fluid
Fluid
Level
Displays the fluid level of the isolation fluid pump.
• 0%
(Empty)
• 50%
• 100%
With color change enabled, the icon displays the fluid level of the isolation fluid pump and the
paint color being used. The color on the pump indicates the pump contents:
• Aqua/cyan color = Unknown fluid; usually flush fluid.
• Dark blue = Paint; the paint number appears to the left of the icon.
• Gray = Air; used when flushing the system.
Spray
Spray
Spray Preset
Preset
Preset
Enter a spray preset number to set the gun fluid pressure. The spray gun symbol indicates that
the number is a spray preset number:
To configure Preset 1 through 99, see
Preset 0 allows the operator to change the settings at any time during operation.
3A8492A
indicates that the ground rod is up and the system is capable of holding a charge.
(Full)
Adjust the Gun Fluid Settings, page
Run Menus
35.
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hydroshield wabh02

Table of Contents