Alcatel-Lucent 7210 SAS M Interface Configuration Manual page 214

Service access switch
Hide thumbs Also See for 7210 SAS M:
Table of Contents

Advertisement

Before enabling the g8032-fast-flood-enable command the user must check if sufficient resources are
available.The tools>dump>system-resources command is available to check if sufficient resources are
available.The field 'Ingress Shared CAM Entries' shown in the output below of tools>dump>system-
resources command, must be more than or equal to 512 (free column in the output shown below).
-------------------------------+-----------+-----------+------------
Ingress Shared CAM Entries
If the configuration file contains a no form of this command, then the system does not allocate any resources
for use by G.8032.The entire resource pool is available for use by ACLs. The no form of the command takes
affect only on reboot.
Default
no g8032-fast-flood-enable
split-horizon-group
Syntax
split-horizon-group group-name
no split-horizon-group
Context
config>lag
config>port
Description
Platforms Supported: 7210 SAS-M, X, T. It is not supported on 7210 SAS-R6, 7210 SAS-R12 and 7210
SAS-Mxp.
This command associates a split horizon group to which this port or LAG belongs. For LAGs, all the
member ports of the LAG are added to the split horizon group. The split-horizon-group must be configured
in the config context.
Configuring or removing the association of the port requires the following conditions to be satisfied:
• There are no applications associated with the port/lag (like SAPs on the port, etc.).
• The port or LAG should be administratively shutdown.
• The port should not be part of a LAG.
• To change split horizon group of a port or LAG, the old split horizon group should be first removed
from the port or LAG, and then the new split horizon group can be configured.
The no form of this command removes the port or all member ports of the LAG from the split horizon
group.
Parameters
group-name — Specifies the name of the split horizon group up to 32 characters in length. The string must
be composed of printable, 7-bit ASCII characters. If the string contains special characters (#, $, spaces,
etc.), the entire string must be enclosed within double quotes.
7210 SAS M, T, X, R6, R12, Mxp Interface Configuration Guide
| Total
| Allocated
| 0
| 0
Interface Configuration
| Free
| 512