Values
revert-time
Syntax
revert-time time
no revert-time
Context
config>eth-ring
This command configures the revert time for an Eth-Ring. It ranges from 60 seconds to 720 second by 1
second intervals.
The no form of this command this command means non-revertive mode and revert time essentially is 0
meaning the revert timers are not set.
Default
300 seconds
Parameters
value — Specifies the guard-time.
Values
ccm-hold-time
Syntax
ccm-hold-time {down down-timeout | up up-timeout}
no ccm-hold-time
Context
config>eth-ring
This command configures eth-ring dampening timers.
The no form of this command set the up and down timer to the default values.
down
Syntax
down down-timeout
Context
config>eth-ring>ccm-hold-time
This command specifies the timer, which controls the delay between detecting that ring path is down and
reporting it to the G.8032 protection module. If a non-zero value is configured, the CPM will wait for the
time specified in the value parameter before reporting it to the G.8032 protection module.
Note: This parameter applies only to ring path CCM. It does NOT apply to the ring port link state. To damp
ring port link state transitions, use hold-time parameter from the physical member port.
Default
0 - the fault will be reported immediately to the protection module.
Parameters
value — Specifies the down timeout.
Values
7210 SAS M, T, X, R6, R12, Mxp Interface Configuration Guide
1—20 deciseconds
60 —720 seconds
0 — 5000 deciseconds