Fuse Block and Fuses
Fuse Block and Fuses Test
Key/Ignition Switch
2000 Series Z MASTER® Service Manual
3438-778 Rev A
The fuse block houses the fuses that protect the electrical system from electrical
surges.
Note: Always use Toro fuses when replacing a damaged or blown fuse.
g336412
1. Visually inspect the fuses. A failed fuse can be identified by a broken or
melted element inside the fuse cover or a damaged spade.
g336414
2. Using a digital multi-meter set to the OHM or Continuity setting, check the
continuity between the fuse blades. If the fuse is OPEN (no continuity),
replace the fuse and test the circuit.
The ignition switch makes the proper connections for the starter, safety
circuits, and accessories. Detents inside the switch control the three switch
positions: OFF, RUN, and START. The START position is spring loaded so that it
automatically returns to the RUN position when released.
Ignition Switch Wiring Connections
Figure 81
Figure 82
Page 8–5
Electrical: Service and Repairs