Description
Electrostatic discharge
The LMI, RMI, and LMX circuit packs are immune to electrostatic discharges typical for an
office environment (carpeted floors, low humidity) using the test method specified by IEC
801-2.
The LMI, RMI, and LMX circuit packs withstand, without malfunction, a direct discharge of up
to +/-15 kV (to user accessible surface and face plate).
No damage or malfunction occurs at up to +/- 20 kV of direct discharge. An indirect discharge
of up to +/- 20 kV does not result in malfunction of the system (to adjacent equipment or
connected cabling).
Safety requirements
• Underwriters Laboratory (UL): The MCR circuit packs comply with and are recognized
under UL 1950, third edition.
• Canadian Standards Association (CSA): The MCR circuit packs comply with and are
certified under CSA C22.2, No. 225 and No. 950-95.
50
Mini-Carrier Remote Fundamentals
Comments? infodev@avaya.com
March 2013