Avaya Communication Server 1000M Single Group Manual page 106

Mini-carrier remote fundamentals
Hide thumbs Also See for Communication Server 1000M Single Group:
Table of Contents

Advertisement

Maintenance
3. Display the alarm log by executing the DISPLAY ALARM (D A), or DISPLAY
106
Mini-Carrier Remote Fundamentals
commands are also discussed on
page 84.
Figure 59: DISPLAY STATUS screen
Figure 60: DISPLAY STATUS DISTANT screen
The responses displayed on the screen show: the firmware version, present time
and date, individual carrier fault threshold parameters, and the present status of
each carrier link.
If a carrier-link mismatch exists, the status will display unequal alarm levels across
a mismatched link. To verify that carrier links are connected correctly at both ends
perform the tests in
Verifying mini-carrier links at the remote site
ALARM DISTANT (D A D) commands. These commands display the list of the
most recent 100 alarms for the near-end (D A) or distant-end (D A D) locations
along with the date and time that each alarm occurred. Both screens are similar to
Figure 61: DISPLAY ALARM (D A) screen
Note:
Invoking the D A and D A D commands display the alarm log. To clear the alarm
log, use the CLEAR ALARM LOG (C A L) and CLEAR ALARM LOG DISTANT
(C A L D) commands.
Figure 61: DISPLAY ALARM (D A) screen
Comments? infodev@avaya.com
DISPLAY STATUS DISTANT (D S D)
on page 106.
on
on page 98.