Nortel CallPilot Installation And Configuration Manual page 99

Hide thumbs Also See for CallPilot:
Table of Contents

Advertisement

October 2000
IF you are installing the
201i server in
an Option 11C Mini
To position the 201i server on the switch shelf
1
Ensure that no cables are connected to the slots in which you are installing the
201i server.
2
Open the lock latches at the top and bottom of the 201i server faceplate.
Note: Opening the top lock latch breaks the yellow backplane warning label, if it
has not been removed.
IF you are installing
the 201i server in
an Option 11C or Option 11C
Mini switch
a Meridian 1 switch
3
Slide the 201i server into an unoccupied pair of slots.
The 201i server requires two consecutive unoccupied slots on the shelf. Ensure
that the 201i server is positioned correctly between the slots.
ATTENTION
4
Connect the SCSI cable to the SCSI connector on the 201i server's faceplate.
5
If you are working with the Option 11C, ensure that the grounding braid on the
intermediate SCSI cable is connected to the card cage.
Part 2: 201i Server Hardware Installation
Installing the server and connecting the peripherals
THEN
install the SCSI cable.
See "Installing the NTRH3502 SCSI cable for
Option 11C Mini" on page 73.
Note: If you have already installed the SCSI
cable, then you have also already installed the
201i server in a pair of slots.
THEN
remove the label and continue with this
procedure.
you must move the secondary backplane
connector. For details, see "Repositioning the
secondary backplane connector" on page 50.
Do not push the 201i server into place against the backplane
yet.
All peripheral devices (monitor, keyboard, mouse, and SCSI
device) must be connected before the 201i server starts. The
201i server receives power and starts as soon as the 201i
server is locked into position on the shelf.