Installing Cables On The Back Of The Option 11C Mini Cabinet - Nortel CallPilot Installation And Configuration Manual

Hide thumbs Also See for CallPilot:
Table of Contents

Advertisement

Installing the server and connecting the peripherals
Installing cables on the back of the Option 11C
Mini cabinet
Introduction
The following items must be installed on the back of the Option 11C Mini cabinet:
multi I/O cable (NTRH0912)
power cord with two ferrites
Before you begin
Ensure that you have the Option 11C Mini EMC Kit (NTRH3503). The kit contains
ferrites that must be installed on the Option 11C Mini's power cord to maintain
Option 11C Mini EMC requirements.
If you do not have the kit, contact your Nortel Networks distributor.
To connect the cables
1
Locate, on the rear of the Option 11C Mini cabinet, the connector associated
with the first slot occupied by the 201i server.
2
Connect the NTRH0912 multi I/O cable as follows:
a. Loosen the connector's Velcro fastening strap.
b. Connect the amphenol connector on the NTRH0912 multi I/O cable to the
connector on the back of the Option 11C Mini cabinet.
c. Secure the connection by tightening the connector's retaining screw and
Velcro fastening strap.