Cabling the NT8D22 System Monitor

1
Remove the I/O safety panel in the rear of the module with CPU 0.
2
Connect the master system monitor to the SDI port.
For options 21, 21E, 51, 51C, 61, and 61C, connect the narrow ribbon
on one of the cables listed below from connector J2 on the backplane to
the assigned port on the SDI card (see Figure 52).
To connect an NT8D41 SDI Paddle Board, use an NT8D46AG
cable.
To any other type of SDI card, use an NT8D46AD cable.
Figure 52
Options 21, 21E, 51, 51C, 61 and 61C—
cable master system monitor to SDI port
Configuring the system monitor
To SDI port
NT8D46AD
or NT8D46AG
Backplane
CPU 0
NT8D46AA
To system monitor/
power supply assembly
in the pedestal
Page 95 of 500
To next module
J2
J1
553-3111
553-3111