Installing PFTUs

Connecting trunks and telephones

The "ground start" feature on 500/2500-type telephones connected to CO
trunks requiring a ground start condition is not required. Automatic ground
start is performed by the PFTU. However, rotary dials (dial pulse) are
required on telephones assigned to trunks that are not equipped to recognize
tone pulses (touch tone).
See the PFTU documentation for MDF cable terminations for telephones and
trunks associated with the PFTU. If the connections are not designated on the
connecting blocks, mark the blocks as shown in the documentation or install
the appropriate designation strips.
1
2
553-3001-210 Standard 14.00 June 1999
For each telephone assigned to the PFTU:
Connect the tip and ring of the line card to the first pair of the
assigned PFTU.
Connect the tip and ring of the telephone to the second pair of the
assigned PFTU.
For each trunk assigned to the PFTU:
Connect the tip and ring of the CO card to the third pair of the
assigned PFTU.
Connect the tip and ring of the trunk to the fourth pair of the assigned
PFTU.